Berkeley Analytical to Offer CDPH Standard Method V1.3 Testing on January 1, 2027
Berkeley Analytical is adding CDPH Standard Method V1.3 (2026) to the scope of its ISO/IEC 17025 accreditation and expects to be among the first indoor air quality laboratories to offer VOC emissions testing under the revised standard. The laboratory will begin testing to this new version of the standard on January 1, 2027. Manufacturers that select this option will have an early opportunity to demonstrate that their products meet the latest VOC emissions criteria.
The updated method introduces emission limits for three additional volatile organic compounds (VOCs) and significantly tightens the existing limit for a fourth. The most notable newly targeted chemicals are trimethylbenzenes and ethylene glycol monobutyl ether (2-butoxyethanol). These are solvents that are known to occur in emissions from some interior building products such as paints and coatings. As a result, the CDPH V1.3 changes may affect products that previously met CDPH V1.2 requirements, making it important for manufacturers to review their existing emissions data and product formulations.
Berkeley Analytical's ClearChem program will also transition to CDPH V1.3 beginning January 1, 2027. All new ClearChem testing initiated on or after this date will follow the updated method, while existing self-declared product claims will retain their original CDPH V1.2 designation.
Key Takeaways
• Effective January 1, 2027: CDPH Standard Method V1.3 adds limits for three new chemicals and tightens the limit for one.
• The two that matter most: trimethylbenzenes and 2-butoxyethanol are both solvents that may be present in emissions from interior products such as paints and coatings.
• Highest risk for customers: any detectable trimethylbenzene emission is likely to exceed the new 2 µg/m³ combined maximum allowable concentration.
• Testing options: Berkeley Analytical will offer V1.3 testing beginning January 1, 2027. V1.2 testing remains available while the market adjusts.
• LEED: LEED v5 still references CDPH V1.2 (2017), but other programs may move sooner.
What Changed?
CDPH V1.3 introduces three new VOC emission limits and tightens one existing limit. The table below summarizes the changes in allowable concentrations compared to CDPH V1.2.
| Chemical | CAS No. | CDPH V1.2 Guideline |
CDPH V1.3 Guideline (effective Jan. 1, 2027) |
|---|---|---|---|
| Trimethylbenzenes (combined) | 25551-13-7; 108-67-8; 95-63-6; 526-73-8 |
Not included | 2 µg/m³ |
| Ethylene glycol monobutyl ether (2-butoxyethanol) |
111-76-2 | Not included | 41 µg/m³ |
| 1-Bromopropane | 106-94-5 | Not included | 1 µg/m³ |
| 1,4-Dichlorobenzene | 106-46-7 | 400 µg/m³ | 2.5 µg/m³ |
The Two Changes Most Likely to Affect Products
Trimethylbenzenes (new limit: 2 µg/m³, combined), often occurring as a mixture of three isomers, are used as solvents because they have moderate volatility and strongly dissolve many organic chemicals. Their primary use is in petroleum blending and gasoline refining. Outside of that use, they are a niche solvent with substantially lower use than 2-butoxyethanol. Even so, they may be present in the formulation and production of interior building products. Because the combined limit is just 2 µg/m³ (0.4 ppb), products with detectable emissions are likely to exceed this value. Thus, trimethylbenzenes pose a high risk of noncompliance.
Ethylene glycol monobutyl ether (new limit: 41 µg/m³), also known as 2-butoxyethanol, is an attractive solvent because it dissolves in both polar and nonpolar substances and mixes easily with water and organic liquids. As product chemistry shifts toward water-based formulations, market demand for it is increasing, so it may be present in the emissions of some products, such as paints and coatings.
Lower-Impact Changes
1,4-Dichlorobenzene (limit tightened from 400 to 2.5 µg/m³) is a solid at room temperature and is associated with moth repellents and bathroom deodorizing products. It is not used as a solvent and is not commonly used in the formulation and production of interior building products, so this change is not expected to have much impact.
1-Bromopropane (new limit: 1 µg/m³) is used industrially in vapor and immersion degreasing, and may also be used as a reactant or intermediate to produce other chemicals. It is not commonly used in the formulation and production of interior building products.
What to Do Now
Manufacturers should review their safety data sheets (SDSs), product formulations, and previous emissions testing reports to determine whether any of these four chemicals have been detected. Focus first on trimethylbenzenes and 2-butoxyethanol, the two most likely to cause a product to fall short of the CDPH V1.3 maximum allowed concentrations.
Testing Options Beginning January 2027
Product testing: Customers will have the option to test samples of their building products against the CDPH Standard Method V1.3 VOC emissions criteria. Manufacturers who select this option can demonstrate that their products meet the latest health-based emission criteria. CDPH Standard Method V1.2 will continue to be a testing option while the market adjusts.
ClearChem: We are committed to keeping Berkeley Analytical’s ClearChem at the forefront of the latest indoor air quality standards. New testing for ClearChem listings beginning in 2027 will be conducted in accordance with CDPH Standard Method V1.3.
Looking Ahead: LEED and Other Programs
As of November 2026, the U.S. Green Building Council (USGBC) has not announced updates to the LEED Low-Emitting Materials and Indoor Air Quality (IAQ) credit requirements to reference CDPH V1.3, and LEED v5 continues to reference CDPH V1.2. Testing under CDPH V1.3 prepares manufacturers for the future adoption of the updated standard across LEED and other green building protocols, some of which may move more quickly. Manufacturers who prepare now can minimize disruption and position their products for future compliance.
Talk to Us
If you have questions about how CDPH Standard Method V1.3 may affect your product portfolio, Berkeley Analytical can help you evaluate your available emissions data and discuss testing options. Email us at info@berkeleyanalytical.com or call 510-236-2325.